To restore the controller to the default settings (Budgeting and Rain Delay settings will remain): 

1. Press the ON button until the START EVERY is displayed and the icon appears on the bottom left of the screen. 

2. Press and hold down the UP BUTTON for three seconds. 

3. The screen returns to the home screen (clock) and all the default settings are restored. The current time and date is retained.



Water is flowing out under the anti-siphon cap: 

CAUSE: Valve is not installed at least 6 in. above the highest outlet on the system

  • SOLUTION: Raise valve up so it is at least 6 in. above the highest outlet on the system 

CAUSE: Anti-siphon float is obstructed or stuck 

  • SOLUTION: Unscrew anti-siphon cap and check float assembly and clear out any debris or foreign material inside.

CAUSE: Valve is installed backwards. 

  • SOLUTION: Reverse valve and make sure arrow on valve body is pointing away from water source


Valve/actuator is not opening automatically or manually: 

CAUSE: No water pressure 

  • SOLUTION: Open main water supply valve 

CAUSE: Faulty solenoid 

  • SOLUTION: Replace solenoid 

CAUSE: Flow control handle is turned down 

  • SOLUTION: Open flow control handle on valve or actuator


Valve/actuator functions in manual mode but not automatically: 

CAUSE: Controller is set to OFF mode 

  • SOLUTION: Verify that controller does not show OFF in current time mode 

CAUSE: AM/PM not set correctly in current time mode 

  • SOLUTION: Check current time, change AM/PM if necessary 

CAUSE: AM/PM not set correctly in start time mode 

  • SOLUTION: Check start time(s), change AM/PM if necessary 

CAUSE: Watering restriction or rain delay is preventing watering 

  • SOLUTION: Remove watering restrictions or set rain delay to off 

CAUSE: Yellow sensor wires have been cut 

  • SOLUTION: Re-connect sensor wires together with waterproof connector 

CAUSE: Sensor is installed and is in a state that prevents watering 

  • SOLUTION: Check sensor and wire splices and verify sensor is normally closed


The display is blank: 

CAUSE: No buttons have been pushed in the previous 15 minutes 

  • SOLUTION: Push any button


Valve/actuator fails to close: 

CAUSE: Valve/actuator is installed backwards 

  • SOLUTION: Check flow arrow and verify arrows points away from water source 

CAUSE: Debris is blocking solenoid port 

  • SOLUTION: Shut off water supply, unscrew and remove solenoid, then open water supply and flush out solenoid port, re-install solenoid


Rain sensor does not prevent watering: 

CAUSE: Rain sensor is normally open, malfunctioning, or not wired correctly 

  • SOLUTION: Verify that sensor icon appears on display when pin is pushed down & check all wire splices


Controller waters more than once per day: 

CAUSE: More than one start time has been programmed 

  • SOLUTION: Change start time 2,3,4, and 5 to OFF


If further assistance is required, DIG offers the following customer support: 

TECHNICAL SERVICE USA 

  • DIG’s Technical Service Team is available to answer questions in English and Spanish from 8:00 AM to 5:00 PM (PST) Monday-Friday (except holidays) at 800-344-2281.

  • Questions in English and Spanish can be emailed to questions@digcorp.com or faxed to 760-727-0282. 

  • Specification documents and manuals are available for download in English and Spanish at www.digcorp.com.

  • DIG Corp

1210 Activity Drive

Vista, CA 92081

800-322-9146


***When reaching out to the manufacturer, please write down the agent's name and let us know what they determined!

DIG Battery Operated (DC) Multi-Station Controller SKU 18707


2 station unit: 

  • SKU 18708

  • VPN 720A-000

  • MFR Part 720A

4 station unit: 

  • SKU 18711

  • VPN 740A-000

  • MFR Part 740A

6 station unit: 

  • SKU 18714

  • VPN 760A-000

  • MFR Part 760A


DIG 7X0A Installation Manual


TO RESTORE THE CONTROLLER TO THE DEFAULT SETTINGS

1. Press left or right arrow until the icon appears in the bottom left of the screen. 

2. Press and hold the up arrow for three seconds. 

3. The screen will return to the home screen with all default settings restored. The current time and date is retained.


Valve is not opening automatically or manually: 

Cause 1: No water Pressure 

  • Solution: Open main water supply valve 

Cause 2: Faulty Solenoid 

  • Solution: Replace solenoid 

Cause 3: Flow control handle is turned down 

  • Solution: Open flow control knob/handle on valve


Valve functions in manual mode but not automatically: 

Cause 1: Controller is set to OFF mode 

  • Solution: Verify that controller does not show OFF on home screen 

Cause 2: Program is set to OFF mode 

  • Solution: Verify that each program does not show OFF on the Watering Frequency screen 

Cause 3: AM/PM not set correctly on current time 

  • Solution: Check AM/PM of current time, change if necessary 

Cause 4: AM/PM not set correctly on start time 

  • Solution: Check AM/PM on start times, change if necessary 

Cause 5: Rain Delay is active 

  • Solution: Set Rain Delay to OFF

Cause 6: Yellow rain sensor wires have been cut 

  • Solution: Reconnect rain sensor wires with a waterproof connector 

Cause 7: Installed rain sensor is preventing watering 

  • Solution: Check sensor and wire splices. Verify that a normally closed rain sensor is used


The display is blank: 

Cause 1: No buttons have been pressed in the previous 15 minutes 

  • Solution: Press any button 

Cause 2: Batteries are dead 

  • Solution: Insert new batteries


Valve fails to close: 

Cause 1: Valve is installed backwards 

  • Solution: Check flow arrows and verify arrows point away from water source 

Cause 2: Debris is blocking solenoid port 

  • Solution: Shut off water supply, unscrew and remove solenoid, then open the water supply to flush out solenoid port. Reinstall solenoid afterwards 

Cause 3: Solenoid is not fully closed 

  • Solution: Turn solenoid clockwise to fully closed position 

Cause 4: Solenoid or adapter O-rings are damaged or twisted 

  • Solution: Turn off the water supply. First, turn the solenoid counter-clockwise to remove and inspect the O-ring, then turn it counter-clockwise and repeat the inspection. Clean any debris or replace the O-ring as necessary 

Cause 5: Static main line pressure is too low 

  • Solution: Verify that static main line pressure is above 10 PSI


Rain sensor does not prevent watering: 

Cause 1: Rain sensor is normally open, malfunctioning, or not wired correctly 

  • Solution: Verify that sensor icon appears on display when pin is pressed down (updates once per minute), check all wire splices


Controller waters more than once per day: 

Cause 1: More than one start time has been programmed 

  • Solution: Check all programs for start times not wanted and set them to OFF


Valve opens at unscheduled times and/or days: 

Cause 1: Current time and/or date are not set correctly 

  • Solution: Verify and re-set current time and date 

Cause 2: Incorrect start times are set 

  • Solution: Check all programs and start times and verify that they are set at the desired time or date


For more troubleshooting assistance, please visit www.digcorp.com or call 760-727-0914.


Should you encounter any problem(s) with this product or if you do not understand its many features, please refer to this instruction manual first. If further assistance is required, DIG offers the following customer support: 


TECHNICAL SERVICE USA: 

  • DIG’s Technical Service Team is available to answer questions in from 8:00 AM to 5:00 PM (PST) Monday-Friday (except holidays) at 760-727-0914. 

  • Questions in English and Spanish can be emailed to: questions@digcorp.com or faxed to 760-727-0282. 

  • Specification documents and manuals are available for download in English and Spanish at www.digcorp.com 

  • DIG Corp

1210 Activity Drive

Vista, CA 92081

800-322-9146


***When reaching out to the manufacturer, please write down the agent's name and let us know what they determined!

Hunter


Hydro-Rain

AC

Hydro-Rain Bhyve Pro Wi-Fi Controller SKU 9026


8 zone unit: 

  • SKU 9028 

  • VPN 04080L

  • MFR Part HRC-400WF-08

16 zone unit: 

  • SKU 9027 

  • VPN 04082

  • MFR Part HRC-400WF-16


HRC 400 Gen 2 Manual


General Q&A: https://hydrorain.com/knowledgebase/ 


One or more valves do not turn on

  1. Faulty solenoid connection 

  2. Wire damaged or severed 

  3. Flow control stem screwed down, shutting valve off 

  4. Programming is incorrect


Stations turn on when they are not supposed to

  1. Water pressure is too high 

  2. More than one start time is programmed 

  3. AM/PM is incorrect 


One station is stuck on and will not shut off

  1. Faulty valve 

  2. Particles of dirt or debris stuck in valve 

  3. Valve diaphragm faulty


All valves do not turn on 

  1. Transformer defective or not connected 

  2. Programming is incorrect


Controller will not power up

  1. Transformer not plugged into a working outlet


Valves continue to turn on and off when they are not programmed

  1. More than one start time is programmed with overlapping schedules 

  2. Excessive pressure


Display says Fault and flashes a zone number 

  1. Short in the wire 

  2. Short in the solenoid



For Hydro-Rain Technical Support and Product Questions:

https://hydrorain.com/support/ 

Toll-Free 888-493-7672

Phone 801-299-5550

Fax 801-203-1179


***When reaching out to the manufacturer, please write down the agent's name and let us know what they determined! 

Bhyve Indoor Wi-Fi Controller SKU13226


4 zone unit: 

  • SKU 13230

  • VPN 57915

  • MFR Part 57915

8 zone unit: 

  • SKU 13227

  • VPN 57925

  • MFR Part 57925


 Bhyve Indoor WiFi Controller manual.pdf 


LED Codes: https://hydrorain.com/knowledgebase/hrc-410-led-codes/ 


General Q&A: https://hydrorain.com/knowledgebase/ 


For Hydro-Rain Technical Support and Product Questions:

https://hydrorain.com/support/ 

Toll-Free 888-493-7672

Phone 801-299-5550

Fax 801-203-1179


***When reaching out to the manufacturer, please write down the agent's name and let us know what they determined!

Bhyve Smart Sprinkler Controller by Orbit SKU15308


6 zone unit: 

  • SKU 15309

  • VPN 57946

  • MFR Part 57946

12 zone unit: 

  • SKU 15313

  • VPN 57950

  • MFR Part 57950


Manual: Orbit Bhyve Controller Manual


General Q&A: https://hydrorain.com/knowledgebase/ 


For Hydro-Rain Technical Support and Product Questions:

https://hydrorain.com/support/ 

Toll-Free 888-493-7672

Phone 801-299-5550

Fax 801-203-1179


***When reaching out to the manufacturer, please write down the agent's name and let us know what they determined!

B-hyve XR Smart Indoor/Outdoor Sprinkler Controller SKU18865


8 zone unit: 

  • SKU18866

  • VPN 57985

  • MFR Part 57985 

16 zone unit: 

  • SKU 18869

  • VPN 57995

  • MFR Part 57995


Manual: B-hyve XR Instruction Manual


Troubleshooting and Q&A: https://support.orbitonline.com/en_us/search?q=xr 


General Q&A: https://hydrorain.com/knowledgebase/ 


For Hydro-Rain Technical Support and Product Questions:

https://hydrorain.com/support/ 

Toll-Free 888-493-7672

Phone 801-299-5550

Fax 801-203-1179


***When reaching out to the manufacturer, please write down the agent's name and let us know what they determined!

DC

Hydro-Rain HRC 990 DC Controller SKU10477

  • VPN 04020

  • MFR Part HRC-990-04-MS


Manual: HRC990 Manual


General Q&A: https://hydrorain.com/knowledgebase/ 


One or more stations do not turn on:

1. Make sure programming is correct.

2. Make sure programming is not in OFF or Rain Delay mode.

3. Remove jack, clean debris, re-plug jack.

4. Clean debris from solenoid.

5. Replace batteries.

6. Replace solenoid.


Stations turn on when they are not supposed to:

1. Reduce water pressure.

2. Check programming to make sure start times are correct. Check A and B programs and start times 1-4.


One station is stuck on and will not shut off:

1. Make sure jack is plugged in.

2. Replace valve.

3. Clean any particles of dirt or debris stuck in valve or solenoid. 

4. Replace valve diaphragm. 

5. Replace solenoid.


All stations do not turn on:

1. Make sure programming is not in OFF or Rain Delay mode.

2. Lack of power due to depleted batteries or faulty solar panel (optional).

3. Programming is incorrect. 


HRC 990 will not power up: 

1. Make sure batteries are installed correctly. 

2. Replace batteries.


Stations continue to turn on and off when they are not programmed to: 

1. Make sure one start time is programmed with no overlapping schedules.

2. Turn down water pressure. 

3. Check A and B programs and start times 1-4.


For Hydro-Rain Technical Support and Product Questions:

https://hydrorain.com/support/ 

Toll Free 888-493-7672

Phone 801-299-5550

Fax 801-203-1179


***When reaching out to the manufacturer, please write down the agent's name and let us know what they determined!


Irritrol

AC

Irritrol Rain Dial-R Series Controller SKU4437


6 station unit:

  • SKU 4438

  • VPN A-RD600-EXT

  • MFR Part RD600-EXT

9 station unit:

  • SKU 4439

  • VPN A-RD900-EXT

  • MFR Part RD900-EXT

12 station unit:

  • SKU 4440

  • VPN A-RD1200-EXT

  • MFR Part RD1200-EXT


R Series Manual Pdf

Quick reference guide


Some valves do not operate:

CAUSE: Possible defective solenoid and/or loose wire connection.

  • SOLUTION: Test and replace the solenoid. Secure wire connections. Check for connection continuity.


No valves operate:

CAUSE: Function Switch in OFF position

  • SOLUTION: Set switch to Run or Manual position

  • CAUSE: Deflective valve solenoid

  • SOLUTION: Test and replace valve solenoid

CAUSE: Loose wire connection

  • SOLUTION: Secure wire connections (especially the common wire or “VC” connection)

CAUSE: Skip Days incorrectly set

  • SOLUTION: Check and reprogram Skip Days schedule option

CAUSE: Start Times set to OFF

  • SOLUTION: Reset Start Times

CAUSE: Rain Delay active

  • SOLUTION: Turn off Rain Delay


Watering at wrong times:

CAUSE: Current Time of day incorrectly set

  • SOLUTION: Reset to current time (correct AM or PM)


Blank display:

CAUSE:  No power

  • SOLUTION: Check circuit breaker panel, wiring connections, transformer and 2A fuse


Program won’t display:

CAUSE: Wrong Function switch setting

  • SOLUTION: Place Function switch in the Run position

CAUSE: Controller is currently in a watering cycle

  • SOLUTION: Check or change program with Function switch in Set Programs


Incorrect display (after a power outage or being unplugged):

CAUSE: Battery is weak, dead or not installed

  • SOLUTION: Remove AC power and battery for one minute. Install/replace battery and restore power


Watering on wrong day:

CAUSE: Watering day schedule not set correctly

  • SOLUTION: Reset Program watering day schedule (p.22 of manual)


Current time is wrong and flashing:

CAUSE: Power outage occurred without battery backup

  • SOLUTION: Install/replace battery and reset time


Display is flashing.“FUS” and station number are shown:

CAUSE: Excessive current load due to shorted wire or defective solenoid

  • SOLUTION: Check wiring and splices for short circuit. Replace defective solenoid


Valve will not turn off (with Function switch in the OFF position)

CAUSE: Valve malfunction or manual On (bleed) mechanism open

  • SOLUTION: Carefully turn solenoid or manual bleed screw if present, clockwise to close and shut off valve. Repair/replace valve as necessary


Irritrol Contact Info:

toll-free at 1-800-634-TURF (8873), Monday through Friday, 7:30 AM to 4:00 PM (Pacific)

www.irritrol.com 


***When reaching out to the manufacturer, please write down the agent's name and let us know what they determined!

Irritrol Rain Dial-R Series Indoor Controller SKU14298

  • VPN RD1200-INT-R

  • MFR Part RD1200-INT-R


Manual: https://www.dripdepot.com/files/4437/irritrol-rain-dial-r-series-211.pdf

Quick Manual: Rain Dial-R Manual Pdf


Some valves do not operate:

CAUSE: Possible defective solenoid and/or loose wire connection.

  • SOLUTION: Test and replace solenoid. Secure wire connections. Check for connection continuity.


No valves operate:

CAUSE: Function Switch in OFF position.

  • SOLUTION: Set switch to Run or Manual position.

CAUSE: Deflective valve solenoid.

  • SOLUTION: Test and replace valve solenoid.

CAUSE: Loose wire connection.

  • SOLUTION: Secure wire connections (especially the common wire or “VC” connection).

CAUSE: Skip Days incorrectly set.

  • SOLUTION: Check and reprogram Skip Days schedule option.

CAUSE: Start Times set to OFF

  • SOLUTION: Reset Start Times

CAUSE: Rain Delay active

  • SOLUTION: Turn off Rain Delay


Watering at wrong times:

CAUSE: Current Time of day incorrectly set.

  • SOLUTION: Reset to current time (correct AM or PM).


Blank display:

CAUSE:  No power

  • SOLUTION: Check circuit breaker panel, wiring connections, transformer and 2A fuse


Program won’t display:

CAUSE: Wrong Function switch setting.

  • SOLUTION: Place Function switch in the Run position.

CAUSE: Controller is currently in a watering cycle.

  • SOLUTION: Check or change program with Function switch in Set Programs.


Incorrect display (after a power outage or being unplugged):

CAUSE: Battery is weak, dead or not installed.

  • SOLUTION: Remove AC power and battery for one minute. Install/replace battery and restore power.


Watering on wrong day:

CAUSE: Watering day schedule not set correctly.

  • SOLUTION: Reset Program watering day schedule (p.22 of manual).


Current time is wrong and flashing:

CAUSE: Power outage occurred without battery backup

  • SOLUTION: Install/replace battery and reset time.


Display is flashing.“FUS” and station number are shown:

CAUSE: Excessive current load due to shorted wire or defective solenoid.

  • SOLUTION: Check wiring and splices for short circuit. Replace defective solenoid.


Valve will not turn off (with Function switch in the OFF position):

CAUSE: Valve malfunction or manual On (bleed) mechanism open.

  • SOLUTION: Carefully turn solenoid or manual bleed screw if present, clockwise to close and shut off valve. Repair/replace valve as necessary.


Irritrol Contact Info:

toll-free at 1-800-634-TURF (8873), Monday through Friday, 7:30 AM to 4:00 PM (Pacific).

www.irritrol.com 


***When reaching out to the manufacturer, please write down the agent's name and let us know what they determined!


Irritrol KD2 Outdoor Series SKU4432


4 station unit:

  • SKU 4433

  • VPN A-KD400-EXT

  • MFR Part KD400-EXT

6 station unit:

  • SKU 4434

  • VPN A-KD600-EXT

  • MFR Part KD600-EXT

9 station unit:

  • SKU 4435

  • VPN A-KD900-EXT

  • MFR Part KD900-EXT


KD2 user guide Pdf

KDS Quick Reference Guide Pdf


The display is blank and the controller does not operate:  

CAUSE: Power is disconnected

  • PROBLEM: Check transformer connections (indoor models). Check the AC service panel for a tripped circuit breaker or GFI and reset.


The valve does not turn on:

CAUSE: Faulty control valve wire connections. 

  • SOLUTION: Check the wire connections at the control valve and controller.

CAUSE: Sensor switch in Active position without a sensor or jumper installed.

  • SOLUTION: Set the sensor switch to Bypass position or add a jumper to sensor terminals.

CAUSE: No station run time duration set

  • SOLUTION: Check station run times. See page 12.


Watering program(s) start at unexpected times: 

CAUSE: Watering program schedules have overlapping start times.

  • SOLUTION: Check program start time schedules. Shorten station run times and/or space start times farther apart.

CAUSE: Water Budget setting over 100% can cause delayed start times.

  • SOLUTION: Check Water Budget and decrease the adjustment % factor as necessary


Controller not watering on the selected active day:

CAUSE: Rain Delay is active. 

  • SOLUTION: Check if Rain Delay is set.

CAUSE: Interval or Odd/Even Mode.

  • SOLUTION: Check if Interval or Odd/Even mode is selected and see if the selected day falls within the Odd, Even or falls between the interval watering schedule.


Irritrol Contact Info:

toll-free at 1-800-634-TURF (8873), Monday through Friday, 7:30 AM to 4:00 PM (Pacific).

www.irritrol.com 


***When reaching out to the manufacturer, please write down the agent's name and let us know what they determined!

Irritrol Total Control Series SKU 4477 


6 station unit:

  • SKU 4478

  • VPN A-TC-6EX-R

  • MFR Part TC-6EX-R

9 station unit:

  • SKU 13463

  • VPN A-TC-9EX-R

  • MFR Part A-TC-9EX-R

12 station unit:

  • SKU 4479

  • VPN A-TC-12EX-R

  • MFR Part TC-12EX-R    

24-station unit:

  • SKU 14541

  • VPN A-TC-24EX-R

  • MFR Part A-TC-24EX-R


 Total Control Manual Pdf


All valves will not turn on automatically:

1. Verify program: station time, watering start times, watering days schedule, current time, current day, water budget, and rain delay

2. Check valve common wire for proper connection. 

3. Check for a shorted station; refer to 

4. “How the electronic circuit breaker works” on page 5. 

5. Ensure the rain sensor (if installed) is properly connected and functioning properly. If the rain sensor is not installed, ensure the SENSOR SWITCH is in the BYPASS position. 

6. Check the fuse, and replace if necessary. See p. 27 of the manual.


Cannot program:

1. Disconnect power to controller for 1 minute. Reconnect power and reprogram. 

2. Install fresh 9-volt alkaline battery. 

3. Verify that all 16 start times are not in use by other programs. 


Controller skips a cycle:

1. Verify watering start times, current time and watering days schedule.


No display:

1. Check power source for tripped circuit breaker. 

2. If program module has been removed, this is a normal battery-saving feature. Turn dial to any position to reactivate display. 

3. Disconnect power to controller for 1 min. Reconnect power and reprogram. 

4. Replace battery 

5. Check fuse, replace if necessary. See p. 27 of manual


Valve stays on:

1. Check station times and water budget.

2. Check for Manual mode; place dial in Run position. 

3. Disconnect valve wire. If still on, valve malfunction is indicated. 

4. Check for manual bleed closure at valve.


Valve will not turn on:

1 . Ensure dial is not in Rain/Off position or Rain Delay mode active. 

2. Verify program: station time, watering start times, watering days schedule, current time, current day and water budget. 

3. Make sure common wire and valve wire are correctly connected. 

4. Check for a shorted station, refer to page 

5. 5. If using sensor, check sensor. 

6. Check for blown fuse. Replace if necessary. See page 27 for fuse replacement information.


“Short” or “Master Valve” is displayed:

1. See “How the Electronic Circuit Breaker Works” on page 5 for troubleshooting information


Waters too often:

1. Too many program start times set. Check each program to determine the number of start times assigned and remove as necessary


Irritrol Contact Info:

toll-free at 1-800-634-TURF (8873), Monday through Friday, 7:30 AM to 4:00 PM (Pacific).

www.irritrol.com 


***When reaching out to the manufacturer, please write down the agent's name and let us know what they determined!


K-Rain

AC

K-Rain Pro EX 2.0 Wi-Fi Enabled Controller SKU8631


Indoor unit:

  • SKU 8632 (indoor)

  • VPN 3202ID-WIFI-KIT

  • MFR Part 3202ID-WIFI-KIT

Outdoor unit:

  • SKU 8633 (outdoor)

  • VPN 3202-WIFI-KIT

  • MFR Part 3202-WIFI-KIT


ProEX 2.0 WiFi Quick Start Guide pdf 

Pro EX 2.0 Controller 

Remote Manual for Pro Ex 2.0 pdf 


The program does not come on automatically:

CAUSE: Dial set to the OFF position

  •  SOLUTION: Set the dial to AUTO

 CAUSE: No Start Time

  •  SOLUTION: Turn the dial to PROGRAM DISPLAY and check the program for start time(s). If missing turn the dial to SET PROGRAM START TIMES and enter a start time(s) if needed (page 5 of manual)

CAUSE: Permanent Day Off Feature is Active

  •  SOLUTION: Change permanent day programming if needed (page 14)

CAUSE: No Primary AC Power

  •  SOLUTION: Restore primary AC power

CAUSE: Today may not be a Scheduled Watering Day

  •  SOLUTION: Turn the dial to PROGRAM DISPLAY and check the program Watering Day(s). If missing turn the dial to SET WATERING DAYS and enter watering day(s) if needed (page 6)

CAUSE: Active or Faulty Rain Sensor

  •  SOLUTION: Check LCD Display for BYPASSED or SENSOR. Set Rain Sensor Switch to the Bypassed position


Display shows a station in operation but no watering occurs:

CAUSE: No Primary AC Power

  • SOLUTION: Restore primary AC power

CAUSE: An Open Circuit in the Valve Solenoid or Wiring has disabled the station (Open Circuit Feature has been disabled – page 12 of manual)

  • SOLUTION: Locate and repair Turning ON the Open Circuit Feature will prevent station operation when the valve solenoid or wiring has disabled the station (page 12 of manual)

CAUSE: Rain Sensor is Active and preventing watering

  • SOLUTION: If a recent rain event has occurred then no action is required. Place Rain Sensor Switch in the BY PASSED position to resume operation. If watering does not resume the Rain Sensor is not operating properly

CAUSE: Sensor Jumper is missing

  • SOLUTION: Replace Jumper


Station(s) does not come on:

CAUSE: No Station Run Time has been set

  • SOLUTION: Turn the Dial to SET STATION RUN TIMES and check program station for run time

CAUSE: A SHORT or OPEN circuit has disabled station operation

  • SOLUTION: Locate and repair SHORT/ OPEN circuit. Error Tone, LED and Display will flash showing affected station(s). To temporarily clear the alarm, turn Dial to OFF position briefly and return Dial to AUTO. Controller will auto reset after repair has been performed


Display is partially or completely blank:

CAUSE: Loss of primary AC power

  • SOLUTION: Check for properly installed electrical installation Check for tripped electrical Breakers or fuses

CAUSE: An electrical surge or strike has damaged the electronics

  •  SOLUTION: Perform a controller RESET. If no permanent damage occurred the controller will accept programing commands and function normally


Station(s) repeat operation:

CAUSE: More than one (1) start time has been programmed

  • SOLUTION: Turn the dial to PROGRAM DISPLAY and check program(s) for additional start time(s). If unwanted start times are present turn dial to SET PROGRAM START TIMES and remove (page 5)

CAUSE: The programs could be stacked

  • SOLUTION: Programs stack when another program start time occurs while another program is still running. Check all programs (A, B and C) and start times (4 per each program)


K-Rain Manufacturing Corp 

ATTN: WARRANTY 1640 Australian Avenue Riviera Beach, FL 33404 

(561) 844-1002 

(561) 842-9493 FAX 

(800) 735-7246 / www.krain.com 


***When reaching out to the manufacturer, please write down the agent's name and let us know what they determined!

K-Rain RPS 46 Mini Controller SKU 7549

  • VPN 3506

  • MFR Part 3506


RPS46 Product Brochure pdf

RPS46 Operation ManualPdf 


No Display:

CAUSE: Faulty transformer

  • SOLUTION: Check fuse. Check field wiring. 

CAUSE: Fuse blown

  • SOLUTION: check transformer


Single station not working:

CAUSE: faulty solenoid coil

  • SOLUTION: Swap faulty station wire on controller terminal block with known working station wire. If the faulty valve still does not work on the known working connection then the solenoid coil is faulty. The panel may need to be repaired.


Fuse blows: 

CAUSE: Incorrect wiring or bad wiring connection.

  • SOLUTION: Check wiring and connections.


No automatic start:

CAUSE: Incorrect programming or blown fuse.

  • SOLUTION: If unit works manually check programming. Check fuse and field wiring.


Buttons on keypad not responding:  

CAUSE: Short on keypad or programming not correct.

  • SOLUTION: Check instruction book to ensure programming correct. If keypad still not responding return panel to supplier or manufacturer.


System coming on at random: 

CAUSE: Too many start times entered on automatic programs.

  • SOLUTION: Check number of start times entered on each program. If programming is correct return panel to supplier or manufacturer.


More than one station coming on at once: 

CAUSE: Damaged main output driver chip.

  • SOLUTION: Check wiring and swap faulty station wire(s) on the controller terminal block with known working station wire. If the same outputs are still locked on, return panel to supplier or manufacturer.


Pump start chattering:

CAUSE: Faulty relay or pump contactor.

  • SOLUTION: Electrician to check voltage on pump relay or contactor.


K-Rain Manufacturing Corp. 

ATTN: WARRANTY 1640 Australian Avenue Riviera Beach, FL 33404 

(561) 844-1002 

(561) 842-9493 FAX 

(800) 735-7246 / www.krain.com 


***When reaching out to the manufacturer, please write down the agent's name and let us know what they determined!

DC

K-Rain BL-KR Battery Powered Bluetooth Controller SKU 6950

***No current troubleshooting guide on this controller per K-Rain 11/08/22


1 station unit:

  • SKU 6951

  • VPN BL-KR1

  • MFR Part BL-KR1

2 station unit:

  • SKU 6952

  • VPN BL-KR2

  • MFR Part BL-KR2

4 station unit:

  • SKU 6953

  • VPN BL-KR4

  • MFR Part BL-KR4

6 station unit:

  • SKU 6954

  • VPN BL-KR6

  • MFR Part BL-KR6


Per K-Rain, please forward troubleshooting requests for this controller to K-Rain. There is no current troubleshooting available for this controller. 


 K-Rain BL-KR Battery Powered Bluetooth Controller Instruction manual pdf 

 Specifications sheet pdf 

Compatible devices pdf 


K-Rain Manufacturing Corp 

ATTN: WARRANTY 1640 Australian Avenue Riviera Beach, FL 33404 

(561) 844-1002 

(561) 842-9493 FAX 

(800) 735-7246 / www.krain.com 


***When reaching out to the manufacturer, please write down the agent's name and let us know what they determined!


RainBird

AC

 RainBird ESP-TM2 Controller SKU 9720 


4 station unit:

  • SKU 9721

  • VPN ESP-TM2-4

  • MFR Part ESP-TM2-4

6 station unit:

  • SKU 9723

  • VPN ESP-TM2-6

  • MFR Part ESP-TM6

8 station unit:

  • SKU 9724

  • VPN ESP-TM2-8

  • MFR Part ESP-TM2-8


Rain Bird ESP-TM2 Controller Manual Pdf

Tech Sheet.pdf 

ESP-TM2-Sell Sheet Brochure pdf 


Watering icon on the display is flashing, but the system is not watering:

CAUSE: Water supply issue

  • SOLUTION: Verify there is no disruption to the main water line and that all other water supply lines are open and functioning.

CAUSE: Wiring is loose, not properly connected or damaged. 

  • SOLUTION: Check that wiring is securely connected at the controller and in the field. Check for damage and replace if necessary. Check wiring connections and replace with watertight splice connectors if needed.


Automatic and/or Manual Watering will not start:

CAUSE: Connected rain sensor may be activated

  • SOLUTION: Let the rain sensor dry out or else disconnect it from the controller terminal block and replace it with a jumper wire connecting the two SENS terminals. 

CAUSE: Jumper wire connecting the two SENS terminals may be missing or damaged.

  • SOLUTION:Jumper the two SENS terminals on the controller terminal block by connecting them with a short length of 14 to 18 gauge wire. 

CAUSE: Solenoid or master valve is shorted.

  • SOLUTION: Confirm short message on the display. Correct the issue in the wiring. Clear the message by testing watering at the shorted valve or by pressing the right arrow button.


Excessive watering:

CAUSE: Programs may have multiple start times that were set unintentionally

  • SOLUTION: Programs (A, B or C) only require a single start time in order to run. Separate start times are not required for each valve.


Display is blank:

CAUSE: Power not reaching the controller.

  • SOLUTION: Verify the main AC power supply is securely plugged in or connected and working properly. Verify the orange power supply wires are connected to the controller “24 VAC” terminals.


Display is frozen and controller will not accept programming:

CAUSE: An electrical surge may have interfered with the controller’s electronics.

  • SOLUTION: Unplug the controller for 2 minutes, then plug it back in. If there is no permanent damage, the controller should accept programming and resume normal operation. If not, Press and release the RESET button.


 www.rainbird.com/esptm2 

Call Rain Bird toll free Technical Support at 1-800-724-6247 (USA and Canada only)


***When reaching out to the manufacturer, please write down the agent's name and let us know what they determined!

RainBird ESP4Me Wi-Fi Compatible Irrigation Controller SKU 8531

  • VPN F55410

  • MFR Part ESP-4ME3


Rain Bird ESP4-ME3 Controller manual pdf 

ESP4-ME3 Quick Guide.pdf 

ESP4-ME3 Tech Specs Pdf


***THIS CONTROLLER HAS BUILT IN ERROR MESSAGES - review manual for error message explanations


Display shows a program is active, but system isn’t watering:

CAUSE: Water source not supplying water.

  • SOLUTION: Verify there is no disruption to the main water line and that all other water supply lines are open and functioning properly.

CAUSE: Wiring is loose or not properly connected.

  • SOLUTION: Check that field wiring and master valve or pump start relay wiring is securely connected at the controller and in the field. 

CAUSE: Field wires are corroded or damaged.

  • SOLUTION: Check field wiring for damage and replace if necessary. Check wiring connections and replace with watertight splice connectors if needed. 

CAUSE: Loss of AC power

  • SOLUTION: When there is a power loss and a 9 volt battery is installed, the system does not irrigate but programs show as remaining active.


NO AC message on display:

CAUSE: No Power detected.

  • SOLUTION: Check circuit breaker and that unit is plugged into socket or properly connected to power source.

CAUSE: Controller may be plugged into a GFCI outlet or an outlet that is wired to a GFCI outlet. 

  • SOLUTION: Check power to the outlet or reset the circuit breaker.


It just rained and the alarm light is not illuminated:

CAUSE: This is normal operation. The ESP-ME3 does not consider the interruption of irrigation due to rainfall as an alarm condition.

  • SOLUTION: This is normal operation.


Programmed schedules do not start:

CAUSE: Connected rain sensor may be activated.

  • SOLUTION: Set Rain Sensor to Sensor OFF to ignore the rain sensor. If watering resumes, the sensor is operating properly and no further correction is needed. 

CAUSE: Connected rain sensor may not be operating properly.

  • SOLUTION: Let the rain sensor dry out, or disconnect it from the controller terminal strip and replace it with a jumper wire connecting the two SENS terminals, or set to Sensor OFF.

CAUSE: If no rain sensor is connected, the jumper wire connecting the two SENS terminals on the terminal strip may be missing or damaged. 

  • SOLUTION: Move dial position to Weather Sensors and set to Sensor OFF.


Too much irrigation:

CAUSE: Multiple Start Times in the same program.

  • SOLUTION: Separate start times are not required for each valve. A program only requires single start time in order to run all stations in that program.

CAUSE: Multiple programs are running at the same time.

  • SOLUTION: Review programming to assure that the same Station is not active in multiple Programs.

CAUSE: Valve is malfunctioning.

  • SOLUTION: Check to see if the ALARM light on the controller is lit solid, then repair or replace the valve if necessary.

CAUSE: Seasonal Adjust setting is too high.

  • SOLUTION: Set Seasonal Adjust to 100%


Display is blank or frozen, the controller will not accept programming or is operating abnormally:

CAUSE: Power not reaching the controller.

  • SOLUTION: Verify the main AC power supply is securely plugged in or connected and working properly

CAUSE: Controller needs to be reset.

  • SOLUTION: Press the Reset Button. For details see “Reset Button” section.

CAUSE: An electrical surge may have interfered with the controller’s electronics.

  • SOLUTION: Unplug the controller for 2 minutes, then plug it back in. If there is no permanent damage, the controller should accept programming and resume normal operation. 


Automatic error detection indicates a problem by ALARM LED and an error message on display:

CAUSE: Short circuit or overload condition in valve, master valve or pump start relay wiring.

  • SOLUTION: Identify and repair the fault in the wiring. Refer to compatible pump start relays. For details see “Connect Pump Start Relay” section.


LED is flashing or solidly illuminated but I see no message on the LCD:

CAUSE: Dial not in AUTO RUN position.

  • SOLUTION: Turn dial to AUTO RUN position. Push Reset button or power cycle the controller.


 www.rainbird.com/esptm2 

Call Rain Bird toll free Technical Support at 1-800-724-6247 (USA and Canada only)


***When reaching out to the manufacturer, please write down the agent's name and let us know what they determined!


Weathermatic(Signature)



Toro

AC

Toro Evolution AG Series Controller SKU8585

  • VPN EVO-4AG

  • MFR Part EVO-4AG


EVO AG Manual Pdf 

EVO AG Quick Start Guide pdf 

EVO AG Info Sheet pdf 


Programming Tech Support: 

1-877-345-8676 

Tech.Support@toro.com 


***When reaching out to the manufacturer, please write down the agent's name and let us know what they determined!

DC

Toro Tempus Waterproof Battery Powered Wireless Controller SKU19087


1 station unit:

  • SKU 19088

  • VPN Tempus-AG-CT-1

  • MFR Part Tempus-AG-CT-1

2 station unit:

  • SKU 19091

  • VPN Tempus-AG-CT-2

  • MFR Part Tempus-AG-CT-2

6 station unit:

  • SKU 19094

  • VPN Tempus-AG-CT-6

  • MFR Part Tempus-AG-CT-6


Toro Tempus AG User Manual pdf 

Toro Tempus AG App User Manual.pdf


Programming Tech Support: 

1-877-345-8676 

Tech.Support@toro.com 


***When reaching out to the manufacturer, please write down the agent's name and let us know what they determined!